PT. Amare Aqila Indonesia

Jl. Merapi Kav. 821, Bukit Nusa Indah, Ciputat, Tangerang Selatan 15414
Telp. 021 7463 9917 (Hunting), Fax. 021-7463 9918

Strobe + Horn Combo

HC-902

Strobe + Horn Combo

Description

  • 8 pcs super bright LEDs
  • High dB sound to alarm
  • With base like smoke detector's base easy install easy change
  • Extremely eye-catching when bright

 

Specification

Input Voltage 12VDC
Alarm Current 250mA
Sound 100dB at 1m

 

 

Buzzer

HC-903

Buzzer

Description

  • High dB sound to alarm
  • With 4 kinds of different sounds to choose
  • With base like smoke detector's base easy install easy change

 

Specification

Input Voltage 12~30VDC
Alarm Current 250mA
Sound 125dB at 1m

 

Buzzer (Electronic Type)

HC-904

Buzzer (Electronic Type)

Description

  • High dB sound to alarm
  • With base like smoke detector's base easy install easy change

 

Specification

Input Voltage 12~24VDC
Alarm Current 180mA
Sound 100dB at 1m

 

Fire Alarm Indicating Lamp

HC-300L

Fire Alarm Indicating Lamp

Description

  • 5 pcs super bright LEDs
  • Connect with Fire Alarm Control Panel, always light in peacetime, when there is an alarm, it will flash to indicate.

 

Specification

Input Voltage 24VDC
Alarm Current 100mA
Size 95mm X 52mm (diameter X height)
Weight 80g

 

Remote Indicating Lamp

HC-200LA

Remote Indicating Lamp

Description

  • Super bright LED (red light)
  • Connect with smoke detector or heat detector directly instead of connecting with Fire Alarm Control Panel, easy and conveniently install.
  • When smoke detector or heat detector alarm, it will light up in the remote area to indicate which detector alarm.

 

Specification

Input Voltage 2VDC
Alarm Current 20mA
Size 119mm X 72mm X 28mm
Weight 60g

 

Remote Indicating Lamp

HC-200LB

Remote Indicating Lamp

Description

  • Super bright LED (red light)
  • Connect with smoke detector or heat detector directly instead of connecting with Fire Alarm Control Panel, easy and conveniently install.
  • When smoke detector or heat detector alarm, it will light up in the remote area to indicate which detector alarm.

 

Specification

Input Voltage 2VDC
Alarm Current 20mA
Size 86mm X 86mm X 23mm
Weight 30g

 

Emergency Exit Indicating Lamp

Emergency Exit Indicating Lamp

Emergency Exit Indicating Lamp

HC-801

Emergency Exit Indicating Lamp

 

Specification

Input Voltage 220VAC
Battery DC6V 2.3Ah
Recharge Time Over 36 hours
Use Time Over 1.5 hours

 

Manual Push Button

HC-1W

Manual Push Button

Description

  • With a base can be used outdoor
  • Resettable, the button can be pushed repeatedly.
  • When there is a fire, push the button, then Fire Alarm Control Panel will send out alarm.

 

Specification

Input Voltage 24VDC
Alarm Current 100mA
Size 138mm X 70mm
Weight 270g
Joint Volume DC-30V 1A

 

Manual Push Button

HC-2W

Manual Push Button

Description

  • Resettable, the button can be pushed repeatedly.
  • When there is a fire, push the button, then Fire Alarm Control Panel will send out alarm.

 

Specification

Input Voltage 24VDC
Alarm Current 100mA
Size 138mm X 48mm
Weight 150g
Joint Volume DC-30V 1A

 

Emergency Lighting

HC-501PL

Emergency Lighting

 

Specification

Rated Consumed Power 13W
Tube 13W
Battery 6V4AH
Recharge Time Over 30 hours
Use Time Over 3 hours

 

Emergency Lighting

HC-502PL

Emergency Lighting

 

Specification

Rated Consumed Power 18W
Tube 18W
Battery 6V4AH
Recharge Time Over 30 hours
Use Time Over 3 hours

 

HC-3WA

HC-3WA

MANUAL CALL POINT

 

Features

  • Alarming by manual pressing, reset by a special key
  • Re-settable (non-breaking glass)
  • With alarm indicating LED and checking bar turn Red
  • Friendly installation and test

 

Specification

Operating Voltage 24VDC
Standby Current 0mA
Alarm Current ≤ 30mA(equivalent resistance is 470Ω/1W)
Visual Indicator Red Illuminates and checking bar turn Red after alarming
Application Indoor use
Dimension (L×W×H) 97×93×49mm(with back box)


Installation
Surface mounting:

First install the back box onto the wall using screws.
Connect cable to manual call point body shown in Fig. 2.
Combine the body and back box by tenon.
Flush mounting: It is not suitable.

 

HC-3WB

HC-3WB

MANUAL CALL POINT

 Add to Inquiry Cart

DM Download (617 KB)

Features

 

  • Alarming by manual pressing
  • After pressing, glass break inside
  • With alarm indicating LED
  • Friendly installation and easy to replace glass

 

Specification

Operating Voltage 24VDC
Standby Current 0mA
Alarm Current ≤ 30mA(equivalent resistance is 470Ω/1W)
Visual Indicator Red Illuminates and checking bar turn Red after alarming
Application Indoor use
Dimension 97×93×49mm (L×W×H)


Installation
Surface mounting :

First install the back box onto the wall using screws.
Connect cable to manual call point body shown in Fig. 2.
Combine the body and back box by tenon.
Flush mounting: It is not suitable.

 

Strobe

HC-901

Strobe

Description

  • 8 pcs super bright LEDs
  • With base like smoke detector's base easy install easy change
  • Extremely eye-catching when bright
  • High lampshade easy to observe form side

 

Specification

Input Voltage 12VDC
Alarm Current 100mA
Sound without

 

Berbagai macam merk dan jenis dari Fire Alarm Control Panel yang beredar di indonesia, akan tetapi masing-masing memiliki kelebihan dan kekurangannya. Kami sebagai distributor dari berbagai merk fire alarm control panel menyediakan stok yang tersedia untuk mempermudah para pemain jasa instalasi fire alarm di indonesia.

PT. Amare Aqila Indonesia sudah sangat berpengalaman dalam menyediakan perlengkapan fire alarm dan menyediakan pemasangan atau instalasi fire alarm baik konvensional maupun addressable.

Segera dapatkan Harga yang menarik dari kami, hubungi :

Tlp. 021 7463 9917 (hunting)
Fax. 021 7463 9918
Hp (Devi). 0858 8225 9931 (WA/LINE)
Hp (Tasya). 0856 7549 032 (WA/LINE)
Email. sales@amare.co.id

Klik >> Donwload Browsur Fire Alarm Control Panel Hong Chang